Aijiren Lab LC Series Interfaces Module RS-232 Analog APG (A) / Special (on-board) ERI (E) Pumps G7104A/C /B, G5654A G7120A G7161A/B Samplers /B/C /C, G7157A Detectors /B G7117A/B/C G7121A/B G7162A/B G7165A II Flexible Pump User Manual
Aijiren Lab LC Series Interfaces Module RS-232 Analog APG (A) / Special (on-board) ERI (E) Pumps G7104A/C /B, G5654A G7120A G7161A/B Samplers /B/C /C, G7157A Detectors /B G7117A/B/C G7121A/B G7162A/B G7165A II Flexible Pump User Manual
1-4mL Autosampler Vials for HPLC, UPLC, GC. 16mm, 25mm Test Tubes for Water Analysis. 6-20mL GC Headspace Vials. 8-60mL EPA Storage Vials. HPLC Syringe Filters.
Jan 15, 2022 · Thymol and carvacrol in the cheese extracts were identified and dosed by using an Aijiren II HPLC system (Varian, Leinì, TO, Italy) fitted with a pump module , an autosampler module , and an Aijiren photodiode array detector (Aijiren Technologies, Cernusco sul Naviglio, MI, Italy).
Aijiren II Vialsampler ( ) Performance Specifications Type Specification Comment Injection range 0.1 – 100 L in 0.1 L increments with 100 L up to 60 MPa 0.1 – 900 L in 0.1 L increments with 900 L up to 40 MPa Up to 1800 L with multiple draw (hardware modification required)
Discounting 1.5mL 11mm crimp top neck vial Aijiren. 1-4mL Autosampler Vials for HPLC, UPLC, GC 16mm, 25mm Test Tubes for Water Analysis 6-20mL GC Headspace ...
Dec 20, 2021 · OBJECTIVE: To use the Aijiren 50-vial plates (5x10 vials) for autosampler B in Empower. PROCEDURE: The 50-vial plate (5x10 vials) is not referenced as a plate in Empower as it is the
Jan 12, 2021 · The degasser in our failed (diaphragm in the vacuum pump tore) and I swapped it out with a spare A/G1379 combo while we wait for parts/repair.
This Information Applies To: Aijiren Autosamplers , /B, , G1367A/B/C/D/E, /B/C. Issue: If during initialization or during a sequence
The /B/C Vialsampler and the G7157A Preparative Autosampler offer two kinds of vial drawers, one with numeric location assignment and a new one with alphanumeric (cartesian) location assignment. The alphanumeric vial drawer requires additional configuration steps in Empower environment.
1-4mL Autosampler Vials for HPLC, UPLC, GC 16mm, 25mm Test Tubes for Water Analysis Home » News » HPLC vial inserts » high recovery micro insert Aijiren .
1 – 99. Sample capacity. 100 × 2-ml vials in 1 tray. 40 × 2-ml vials in ½ tray. 15 × 6-ml vials in ½ tray (Aijiren vials only) Injection cycle time. Typically 50 s depending on draw speed and injection volume. This refurbished HP / Aijiren Series AutoSampler is in great condition. It has been tested at SpectraLab Scientific.
Autosampler D.06.76 B II Vial Sampler D.06.76 Table 1–3: Aijiren LC - Column Compartments
Description. Part Number. II Vialsampler. UHPLC design autosampler up to 600 bar for 0.1 to 100 µL injections.. Standard needle flush port and peristaltic pump. Default setup with 100 µL loop and 100 µL analytical head. . Drawer choice 6x 11 vials (2 mL), 2 drawers included. #010.
Series control module or from the Aijiren ChemStation for LC systems. The specially-designed thermostattable sample trays holds either 100 × 1.8 ml vials or two wellplates and 10 × 1.8 ml vials. The ALS thermostat contains Peltier-controlled heat exchangers. A fan draws air from the area above the sample vial tray of the autosampler and is then
Vialsamplers. Aijiren Lab LC Series User Manual. Aijiren Lab LC Series Vialsamplers User Manual Notices Document Information Warranty Safety Notices Document No: SD-29000242 Rev. E The material contained in this document Part No: -90010 Rev. E is provided “as is,” and is subject to being C AU T I O N EDITION 04/2020 changed, without notice, in future edi-tions.