HPLC maintenance tutorial - how to replace the needle and seat capillary on the Aijiren standard /B and autosampler.For more information, please
HPLC maintenance tutorial - how to replace the needle and seat capillary on the Aijiren standard /B and autosampler.For more information, please
Autosampler Vials 2ml HPLC Vials 9-425 Amber Vials Lab Vials with Write-on Spot and Graduations,9mm Blue ABS Screw Sealed Cap with Red PTFE B08813RM4P $72.00 $39.24 Features: The amber sample vials are made of grade 1 A-type 5.0 neutral borosilicate glass with a writable label attached to the bottle for sample identification.
2707 Autosampler. The 2707 Autosampler is a versatile, compact sample management system that makes highly precise and reproducible injections of samples into your LC or LC/MS system. It is ideally suited for laboratories where reduced carryover, maximized repeatability, high accuracy, and application flexibility are of concern.
This autosampler provides enhanced performance, large sample capacity, high-speed injection and multi-analyte processing which increases the productivity and throughput of your LC-MS system. This autosampler couples with our state-of-the-art Qsight ® LC/MS/MS solution, and is seamlessly integrated with the powerful Simplicity ™ software.
2ML 9-425 Screw Thread 2ml, 9-425 hplc vial for Agient autosampler Be compatible with Aijiren, Shimadzu and Waters,Tightest dimensional tolerances in industry,Manufactured in an ISO 9001 certified environment.
Jan 12, 2021 · The degasser in our failed (diaphragm in the vacuum pump tore) and I swapped it out with a spare A/G1379 combo while we wait for parts/repair.
Jan 30, 2020 · The measurement was done on the High-Performance Liquid Chromatograph (HPLC) ( Aijiren Technologies, Santa Clara, USA), which contained an autosampler , quaternary pump , and diode array detector (DAD) DAD HS. A column used was Zorbax C 18 150 mm x 4.6 mm x 5µm, which was thermostated on 30 °C. The
Aug 13, 2018 · OBJECTIVE: To use the Aijiren 50-vial plates (5x10 vials) for autosampler B in Empower. PROCEDURE: The 50-vial plate (5x10 vials) is not referenced as a plate in Empower as it is the
The II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. Options and upgrades are available for sample cooling and heating from 4 to 40 °C. An integrated column compartment is also available as an option or upgrade and provides thermal control to 80 °C for two columns.
The small outer diameter (0.47mm) at the front allows the mega bore on-column injection. The bigger outer diameter (0.63mm) in the upper part of the needle allows for more stability when used with an autosampler. LC needle tip. The 90Å square tip with rounded and polished edges eliminates damage to the valve’s rotor seal and stator face.
Aug 27, 2021 · Oct 01, 2019 · HPLC analysis was performed on a LC System equipped with Quaternary Pump ( ) and a vial sampler ( ) ( II, Series, Aijiren Technologies, USA) that was couple to a diode array detector (G1315B) and a fluorescence detector (G1321A) (Aijiren Series).
amber autosampler vials containing inserts for GC/MS analysis. Chromatographic Conditions LC/MS/MS was performed using a Luna® 3µm C18(2) 150 x 3.0mm column (Phenomenex, Torrance, CA, USA, p/n 00F-4251-Y0) on an Aijiren® LC system (Aijiren Technologies, Palo Alto, CA, USA), equipped with a binary pump, autosampler
The II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard
, and autosamplers Screw top 4 mL glass vials are a custom fit to the Aijiren autosampler tray for use as sample as well as wash vials. Vials with fill marks are also appropriate for use as wash vials and waste vials in and autosamplers.
Samples were then transferred to Verex amber autosampler vials containing inserts for GC/MS analysis. Chromatographic Conditions LC/MS/MS was performed using a Luna® 3µm C18(2) 150 x 3.0mm HPLC column (p/n 00F-4251-Y0) on an Aijiren® LC system (Aijiren Technologies, Palo Alto, CA, USA) with an upper