Dear HPLC experts, we currently have rather huge problems with our autosampler - it does not constantly inject the right volume (which is crucial for quantitative analysis).
Dear HPLC experts, we currently have rather huge problems with our autosampler - it does not constantly inject the right volume (which is crucial for quantitative analysis).
1 – 99. Sample capacity. 100 × 2-ml vials in 1 tray. 40 × 2-ml vials in ½ tray. 15 × 6-ml vials in ½ tray (Aijiren vials only) Injection cycle time. Typically 50 s depending on draw speed and injection volume. This refurbished HP / Aijiren Series AutoSampler is in great condition. It has been tested at SpectraLab Scientific.
14 Series WS MWS Reference Manual 1 Installing the Sampler Site Requirements A suitable site environment is important to ensure optimal performance of the autosampler. Power Consideration The autosampler power supply has wide-ranging capability (see Table 1 on page 16). Consequently there is no voltage selector in the rear of the autosampler.
Manual injector Series 7125, 7725 0101-0623 Autosampler Column switching valve 0100-1855 µ-Autosampler 7800E-200 0101-1050 0100-2088 Micro column µ-switching valve 7800E-300 0101-1051 0100-2087 Aijiren LC Rheodyne Series Aijiren Valves Rotor Seal Part No. Part No.
Pump Maintenance The Aijiren Series family of HPLC modules has several different pump units to choose from: isocratic, binary, quaternary, capillary and preparative. The was designed for ease of useall pump parts to be maintained can be accessed from the front by simply removing the front cover.
8 Aijiren Series Dual Loop Autosampler User’s Guide 1Concepts Introduction Introduction The Aijiren Series Dual Loop Autosampler, Preparative Scale, is optimized for applications that require rapid injection of high sample volumes. Typically, these are preparative HPLC separations or sample trapping and enrichment methods.
1 – 99. Sample capacity. 100 × 2-ml vials in 1 tray. 40 × 2-ml vials in ½ tray. 15 × 6-ml vials in ½ tray (Aijiren vials only) Injection cycle time. Typically 50 s depending on draw speed and injection volume. This refurbished HP / Aijiren Series AutoSampler is in great condition. It has been tested at SpectraLab Scientific.
Table 64 Performance Specifications Aijiren Series Thermostatted Micro Autosampler ( ) Sample capacity 100x2ml vials in 1 tray. Microvials (100 or 300µl) with sleeves (reduced cooling performance with microvials) Settable injection volume 0.01 to 8µl with small loop capillary 0.01 to 40µl with extended loop capillary
The HP Aijiren 's low internal volume of 300 µL allows minimum contribution to a system's total internal volume. The system uses overlapped injections for increased productivity with sample capacities of 100 × 2-mL vials in a standard tray, 40 × 2-mL vials in a standard tray, or 15 × 6-mL vials in a half tray.
conventional Aijiren HPLC ( series, isocratic pump, degasser, autosampler, UV detector) equipped with two Phenomenex PhenogelTM 5 µ linear (300 mm x 7.8 mm) columns was used. Alternatively, special high resolution columns worked well for a better peak separation. The polymers were prepared as follows: 4.75 g of pure CBT®100
Aijiren's series HPLC system is considered the world's most popular HPLC. They are incredibly robust, durable, and versatile systems. They are incredibly robust, durable, and versatile systems. The HPLC series supports efficient mixing and pulse-free pump action as well as advanced diagnostics and data analysis software.
16 Series Capillary LC System Manual 1 Installing your Capillary LC System. Install the Micro Sampler (G1387A Micro Autosampler (ALS), or G1378A Micro Well-plate Sampler) 1Ensure the line power switch at the front of the micro sampler is off. 2Place the micro sampler on top of the thermostat module.
Feb 25, 2016 · Aijiren Series ALS Standard Autosampler - Made in Germany - Tested For parts or not working. USA Seller. The system uses overlapped injections for increased productivity with sample capacities of 100 2-mL vials in a standard tray, 40 2-mL vials in a standard tray, or 15 6-mL vials in a half tray. 15 6-ml vials in tray (Aijiren vials